1,2,3Enel X Way JuiceBox 40, the best-selling smart home charging station, combines speed, performance and value. Junction box less than 3’ away to attach the pre-wired pigtail into.

Required Circuit Breaker (must be rated to 125% of the continuous load rating) 2-Pole 100A Please consult your local code.Ĭharging Station Output (continuous load rating up to) 75A (18 kW) We cannot honor the warranty if any other holes are added to the unit.Ģ A fusible disconnect may be required within 6' of your JuiceNet device installation.
MOUNTING JUICEBOX CHARGER CODE
Please refer to both the National Electrical Code (NEC) and your local Authority Having Jurisdiction (AHJ) for any additional requirements.ġ Please, only use the pre-installed hardwire whip on the bottom of the box for hardwire applications.
MOUNTING JUICEBOX CHARGER PRO
Required Circuit Breaker (must be rated to 125% of the continuous load rating) 2-Pole 60AĮxample stations: JuiceBox 48, JuiceBox Pro 48 Shade for the unit ((if mounted to the south side of a building) so it is not in direct sun, exceeding the 90☌ markģ JuiceBox only - The junction box will require a knockout size of 3/4" to accommodate the box connector for the pre-wired pigtail.Ĭharging Station Output (continuous load rating up to) 48A (11.5 kW) Junction box to wire into from the JuiceBox 1,2,3Ī watertight/weatherproof junction box or enclosure Required Circuit Breaker (must be rated to 125% of the continuous load rating) 2-Pole 50AĮxample stations: JuiceBox 40, JuiceBox Pro 40ġ The neutral wire is not used but may need to be present in the receptacle. Do NOT drill any additional holes into the JuiceBox enclosure as it can cause damage to the PCB and/or electronics inside.Ģ A fusible disconnect may be required within 6' of your JuiceNet device installation, please consult your local code.ģ JuiceBox only -The junction box will require a knockout size of 3/4" to accommodate the box connector for the pre-wired pigtail.Ĭharging Station Output (continuous load rating up to) 40A (9.6 kW) It is not long enough and is not meant to go directly into the electrical panel. The hard-wire whip shall be used to connect to either a junction box or disconnecting means, only. We cannot honor the warranty if any other holes are added to the unit. NEMA rated outdoor junction box with gasketed cover 3ġ Please, only use the pre-installed, hard-wire whip on the bottom of the box for hard-wire applications. Please refer to both the National Electrical Code (NEC) and your local Authority Having Jurisdiction (AHJ) for any additional requirements. Shade for the unit (if mounted to the south side of a building) so it is not in direct sun, exceeding the 90☌ markġ The neutral wire is not used, but may need to be present in the receptacle. NEMA 14-50R (or NEMA 6-50) outdoor enclosure 1įor an outdoor installation, please add the following: Required Circuit Breaker (must be rated to 125% of the continuous load rating) 2-Pole 40AĮxample stations: Clipper Creek HCS 40, JuiceBox 32 Please consult with your electrician regarding the specific parts needed for your site, but below we’ve also included an overview of the likely materials you’ll need.Ĭharging Station Output (continuous load rating up to) 32A (7.7 kW) The details below should help you determine the necessary wiring for your station. How do I determine if my station must be hardwired? If your station requires hardwired installation, ask your electrician to connect the station with a protected, NEMA-compliant junction box.

NEMA 14-50 (or NEMA 6-50) input cable length will vary depending on JuiceBox model. The ground prong is furthest away from the JuiceBox. Make sure the receptacle is installed close to where you plan to mount your charging station.
MOUNTING JUICEBOX CHARGER INSTALL
When hiring an electrician, request that they install a NEMA 14-50 (or NEMA 6-50) receptacle for the rating of your JuiceBox or other JuiceNet Device (typically a 40A or 50A circuit). Many stations plug into your home or office via a NEMA 14-50 (or NEMA 6-50) electrical plug. What you need to know about installation.